TEL:+86  18658825158
whatsapp:13336078187
Email:zhejiangxinzhao@163.com


Products
Inlet electromagnetic flowmeter 1
Collection

Inlet electromagnetic flowmeter 1

Purpose: used for real-time online monitoring, display, and transmission of volume flow of conductive liquids and slurries in closed pipelines.
Form: electromagnetic induction principle
Flow direction: forward, reverse, net flow, range ratio: 150:1; capable of bidirectional flow measurement, bidirectional total accumulation
Repeatability error: +0.1% of measured value
Accuracy class: DN≤600: 0.5 class;
Measured medium temperature: ordinary rubber liner; -20 to +60°C; high-temperature rubber liner; -20 to +90°C; PTFE liner; -30 to +100°C; high-temperature type PTFE liner; -30 to +180°C
Rated working pressure: pipeline type: DN100: =1.0Mpa Conductivity range: measured fluid conductivity =5 μs/cm
Current output: load resistance: 0-10mA, 0-1.5kΩ; 4-20mA, 0-750Ω
Digital frequency output: output frequency upper limit can be set within 1-5000HZ, with photoelectric isolation transistor open-collector bidirectional output. External power supply ≦35V, maximum collector current when conducting i
comment:0
Collection:0
product warranty
正品保证
快速发货
Product Details
Review(0)

Applications: Used for real-time online monitoring, display, and transmission of volumetric flow rate of conductive liquids and slurries in closed pipelines.

form:Electromagnetic induction principle

Flow direction: forward, reverse, net flow rate, range ratio:

150:1; Capable of bidirectional flow measurement and bidirectional total accumulation.

Repeatability error: the error of the measured value+0.1%

Accuracy class:DN≤600: Grade 0.5;

Temperature of the measured medium: ordinary rubber lining;

-20 to +60℃; High-temperature rubber lining; -20 to +90℃; PTFE lining; -30 to +100℃; High-temperature type

PTFE lining;-30-+180℃

Rated working pressure:Pipeline type:DN100:=1.0Mpa Conductivity range: conductivity of the fluid being measured=5 μs/cm

Current output: Load resistance:At 0-10mA, the resistance is 0-1.5kΩ; at 4-20mA, the resistance is 0-750Ω.

Digital frequency output: The upper limit of the output frequency can be...Bidirectional output with open collector and opto-isolation within 1-5000Hz. Maximum collector current is 250mA when external power supply ≤35V is applied.

Power supply:power supply:220V AC,50Hz

Connection method: Flange connections are used between the flow meter and the piping, and the flange connection dimensions conform to...GB11988 provisions

Ambient temperature:-25℃-+60℃

Relative temperature:5%-95%

Total power consumption: less than15W

Flow measurement range: Flow velocity range0.1-15m/s

Display: High-definition backlight with wide temperature rangeLCD display
杭州富宇泽环保科技有限公司
Hangzhou Fuyu Ze Environmental Protection Technology Co., Ltd.

  电  话:400-835-6877

                   0571-63371995

       传   真:0571-63373132  

  邮 箱:fuyuzehuanbaokeji@163.com