Principle: A gas flowmeter designed based on the thermal diffusion principle. Application: Used for measuring the flow rate of common steady-state gases.
Structure type: Insertion type
Measurement medium: Common steady-state gases
Pipe diameter range:DN100~DN500
Flow velocity range: (0.1~100) Nm/s
Accuracy: ±2.5%
Working temperature: Sensor: (-40~+300) ℃; Converter: (-20~+45) ℃
Working pressure: Medium pressure ≤2.5MPa
Power supply: AC 220V; DC 24V, power should be greater than 18W
Response speed: 1s
Output signal: (4~20) mA (photoelectric isolation, maximum load 500 Ω), RS485 (photoelectric isolation)
Alarm: 1-2 normally open contacts
On-site display: Four-line Chinese character LCD display
Display content: Mass flow rate, standard volume flow rate, accumulated flow rate, standard time, standard flow velocity, etc.
Protection level: IP65
Sensor material: Stainless steel
No temperature and pressure compensation is required for gas flow measurement, making the measurement convenient and accurate, and capable of obtaining the mass flow rate or standard volume flow rate of the gas;
Good seismic performance and long service life. The sensor has no moving parts or pressure sensing components, and is not affected by vibration on measurement accuracy;
Digital design. Overall digital circuit measurement, with accurate measurement and convenient maintenance;
Uses RS485 communication