Sludge Return Electromagnetic Flowmeter 1
Collection

Sludge Return Electromagnetic Flowmeter 1

Purpose: Used for real-time online monitoring, display, and transmission of volume flow of conductive liquids and slurries in closed pipelines.
Form: Electromagnetic induction principle
Flow direction: Forward, reverse, net flow; Turndown ratio: 150:1; Capable of bidirectional flow measurement and bidirectional totalization
Repeatability error: ±0.1% of measured value
Accuracy class: DN≤600: Class 0.5;
Temperature of measured medium: Ordinary rubber lining; -20-+60℃; High-temperature rubber lining; -20-+90℃; PTFE lining; -30-+100℃; High-temperature PTFE lining; -30-+180℃
Rated working pressure: Flange type: DN100: =1.0Mpa; Conductivity range: Conductivity of measured fluid ≧5 μs/cm
Current output: Load resistance: 0-10mA: 0-1.5kΩ; 4-20mA: 0-750Ω
Digital frequency output: Output frequency upper limit can be set within 1-5000HZ, with photoelectric isolation and transistor open-collector bidirectional output. External power supply ≦35V; maximum collector current when conducting is 250mA
comment:0
Collection:0
product warranty
正品保证
快速发货
Product Details
Review(0)

Applications: Used for real-time online monitoring, display, and transmission of volumetric flow rate of conductive liquids and slurries in closed pipelines.

form:Electromagnetic induction principle

Flow direction: forward, reverse, net flow rate, range ratio:

150:1; Capable of bidirectional flow measurement and bidirectional total accumulation.

Repeatability error: the error of the measured value+0.1%

Accuracy class:DN≤600: Grade 0.5;

Temperature of the medium being measured: ordinary rubber lining;

-20 to +60℃; High-temperature rubber lining; -20 to +90℃; PTFE lining; -30 to +100℃; High-temperature PTFE lining; -30 to +180℃

Rated working pressure:Pipeline type:DN100: =1.0Mpa, Conductivity range: conductivity of the fluid being measured≧5 μs/cm

Current output: Load resistance:At 0-10mA, the resistance is 0-1.5kΩ; at 4-20mA, the resistance is 0-750Ω.

Digital frequency output: The upper limit of the output frequency can be...Bidirectional output with open collector and opto-isolation within 1-5000Hz. Maximum collector current is 250mA when external power supply ≤35V is applied.

Power supply:power supply:220V AC,50Hz

Connection method: Flange connections are used between the flow meter and the piping, and the flange connection dimensions conform to...GB11988 provisions

Ambient temperature:-25℃-+60℃

Relative temperature:5%-95%

Total power consumption: less than15W

Flow measurement range: Flow velocity range0.1-15m/s

Display: High-definition backlight with wide temperature rangeLCD display

杭州富宇泽环保科技有限公司
Hangzhou Fuyu Ze Environmental Protection Technology Co., Ltd.

  电  话:400-835-6877

                   0571-63371995

       传   真:0571-63373132  

  邮 箱:fuyuzehuanbaokeji@163.com

                     fyzhbkj@126.com 

  地 址:杭州富阳区富春街道湖塍村 